A Real Estate inspection is a non-invasive physical
examination, performed for a fee, designed to identify material
defects in the systems, structures, and
components of a building as they exist at the time
of the inspection. The specific systems, structures
and components of a building to be examined
are listed in these Standards of Practice.
-
A material defect is a condition that significantly
affects the value, desirability, habitability, or safety
of the building. Style or aesthetics shall not be
considered in determining whether a specific system,
structure, or component is defective.
-
These
Standards provide inspection guidelines, make public
the services provided by private fee-paid inspectors,
and define certain terms relating to these inspections.
-
Sections
1 through 10 of these Standards are a mandatory part of
all such inspections. Sections 11 through 12 are
optional.
-
Unless
otherwise agreed between the inspector and client,
these Standards shall apply to the primary building
and its associated primary parking structure. The
inspection shall be limited to those specific systems,
structures and components that are present
and visually accessible. Components and systems
shall be operated with normal user controls
only and as conditions permit. Inspections
performed in accordance with these Standards are not intended
to be technically exhaustive.
-
Inspection reports shall describe and identify
in written format the inspected systems, structures,
and components of the building and shall identify
material defects.
-
Inspection
reports may contain recommendations regarding conditions
reported or recommendations for further evaluation
by appropriate persons.
-
SECTION
1 - Foundations, Basements, and Under-floor Areas
-
Items
to be identified and reported:
-
Foundation
and other support components.
-
Under-floor ventilation.
-
Location of opening(s) entered to each accessible
under-floor area.
-
Wood separation from soil.
-
Presence of drainage systems or sump pumps within
foundation footprint.
-
Presence or absence of seismic anchoring and bracing components.
-
The
inspector is not required to:
-
Enter
under-floor areas that are not accessible or where
entry could cause damage or pose a hazard to the inspector.
-
Move stored items, vegetation or debris, or perform any
excavations or other intrusive testing to gain access.
-
Operate or evaluate adequacy of sump pumps
or drainage systems.
-
Identify
size, spacing, location or adequacy of foundation bolting
and bracing components or reinforcement systems.
-
Perform any intrusive examination or testing, or
use any special equipment such as, but not limited
to, levels, probes or meters.
SECTION
2 - Exteriors
-
Items to be identified and reported:
-
Surface
grade, hardscaping and drainage within six feet of the
inspected building or associated primary parking
structure.
-
Wall
cladding, veneers, flashing, trim, eaves, soffits and
fascias.
-
Exterior portions of a representative sampling
of doors and windows.
-
Attached decks, porches, balconies, stairs, columns, walkways,
guard-rails and handrails.
-
The
inspector is not required to:
-
Operate or evaluate any mechanical, electro-mechanical,
or underground drainage systems.
-
Operate or evaluate storm windows, storm
doors, screening, shutters or awnings.
-
Operate or evaluate remote-control devices.
-
Examine detached buildings and structures
(other than the primary parking structure), patio
enclosures, fences, and retaining walls.
-
Examine items not visible from a readily accessible
walking surface.
SECTION
3 - Roof Coverings
-
Items to be identified and reported:
-
Roof
coverings.
Flashing,
vents, skylights and other penetrations.
Roof
drainage systems.
-
The
inspector is not required to:
-
Walk on the roof surface if, in the opinion of the inspector,
there is a possibility of damage to the surface or a hazard
to the inspector.
Perform a water test, warrant or certify against roof
leakage or predict life expectancy.
SECTION
4 - Attic Areas and Roof Framing
-
Items to be identified and reported:
-
Framing
and sheathing.
-
Access opening(s) and accessibility.
-
Insulation material(s).
-
Ventilation.
-
The
inspector is not required to:
-
Enter attic areas that, in the opinion of the inspector,
are not accessible or where entry could cause damage.
-
Remove insulation materials or identify composition or
"R" value of insulation material.
-
Activate thermostatically operated fans.
SECTION
5 - Plumbing
-
Items to be identified and reported:
-
Supply, waste, and vent piping.
-
Fixtures, faucets and drains.
-
Water heating equipment, including combustion air, venting,
connections, energy sources, seismic bracing, and temperature-pressure
relief valves.
-
Functional
flow of water supply and functional drainage
at fixtures.
-
Gas piping and connectors.
-
Cross-connections.
-
The
inspector is not required to:
-
Operate
any valve other than fixture faucets and hose faucets
attached to the building.
-
Operate any system, fixture or component
which is shut down or disconnected.
-
Examine
or verify operation of water supply or pressure assistance
systems, including, but not limited to: wells,
pumps, tanks, and related equipment.
-
Verify
functional flow or pressure at any fixture
or faucet where the flow end is capped or connected to
an appliance, or measure pressure, volume or temperature.
-
Examine
or operate any sewage disposal system or
component including, but not limited to: septic
tanks and/or any underground system or portion
thereof, or ejector pumps for rain or waste.
-
Examine the overflow device of any fixture.
-
Evaluate
the potability of water, compliance with local or state
conservation or energy standards, or proper design or
sizing of any water, waste, and venting components,
fixtures, or piping.
-
Identify
whether water supply and waste disposal systems
are public or private.
-
Evaluate
time to obtain hot water at fixtures, or perform
testing of any kind to water heater elements.
-
Examine
ancillary systems or components such as,
but not limited to: those relating to solar water heating,
hot water circulation, yard sprinklers, water conditioning,
swimming pools or spas and related equipment, and fire
sprinklers.
-
Test
shower pans for leakage or fill any fixture with
water during examination.
-
Evaluate
the gas supply system for leaks or pressure.
-
Determine
effectiveness of anti-siphon, back-flow prevention, or
drain-stop devices.
-
Determine
whether there are sufficient clean-outs for effective
clearing of drains.
-
Evaluate
gas, liquid propane, or oil storage tanks.
SECTION
6 - Electrical Systems
-
Items
to be identified and reported:
-
Service conductors, equipment, and capacity.
-
Panels and overcurrent protection devices.
-
Service and equipment grounding.
-
Wiring types and methods.
-
A representative sampling of switches, receptacles,
and light fixtures.
-
Ground-fault circuit-interrupters.
-
The
inspector is not required to:
-
Operate
electrical systems or components which are
disconnected or shut down.
-
Disconnect
any energized system or appliance.
-
Remove
deadfront covers where not accessible, or if removal
could cause injury or damage to persons or property, or
remove device cover plates.
-
Operate
overcurrent protection devices, or evaluate compatibility
of overcurrent protection devices with the panelboard manufacturer.
-
Examine or test smoke detectors.
-
Operate
ground-fault circuit-interrupter devices by other than the
manufacturer's test button.
-
Examine
de-icing equipment, or private or emergency electrical supply
sources, including but not limited to: generators, windmills,
photovoltaic solar collectors, or battery or electrical
storage facilities.
SECTION
7 - Heating Systems
-
Items
to be identified and reported:
-
Heating equipment and operation using normal user controls.
-
Venting
systems.
-
Combustion
and ventilating air.
-
Energy
source and connections.
-
Heating
distribution system(s) including a representative
sampling of ducting, duct insulation, outlets, radiators,
piping systems and valves.
-
The
inspector is not required to:
-
Examine or evaluate condition of
heat exchangers.
-
Determine uniformity, temperature, airflow or balance
of heat supply to any room or building, or examine
for warming at any heating system distribution
component when access would require steps or a
ladder, or determine leakage in any ductwork.
-
Examine electric heater elements or heat pump fluid/gas
materials, or examine below ground/slab systems,
ducts, fuel tanks and related components.
-
Determine
or examine thermostat calibration, heat anticipation,
or automatic setbacks or clocks.
-
Examine radiant or geothermal heat pump systems.
-
Examine any solar-energy heating systems
or components.
-
Examine electronic air filtering systems.
-
Operate heat pump systems when the ambient
air temperature may damage the equipment, or operate
any heat pump system in "emergency" heat mode.
-
Examine humidity control systems and components.
SECTION
8 - Central Cooling Systems
-
Items to be identified and reported:
-
Cooling
equipment and operation using normal user controls.
-
Cooling
distribution system(s) including a representative
sampling of ducting, duct insulation, outlets, piping
systems and valves.
-
Energy
source and connections.
-
4.
Condensate drains.
-
The inspector is not required to:
-
Determine
uniformity, temperature, airflow or balance of cool air
supply to any room or building, or examine
for cooling at any cooling system distribution
component when access would require steps or a
ladder, or determine leakage in any ductwork.
-
Examine electrical current, coolant fluids or gases,
or coolant leakage.
-
Examine electronic filtering systems.
-
Determine or examine thermostat calibration,
cooling anticipation, or automatic setbacks or clocks.
-
Examine any non-central cooling unit(s) or gas-fired,
solar or geothermal cooling system or food, wine
or similar storage cooling system.
-
Examine humidity control systems and components.
SECTION
9 - Fireplaces and Chimneys
-
Items
to be identified and reported:
-
1.
Chimneys, flues, dampers and associated components.
-
2.
Fireboxes, hearth extensions and permanently installed
accessory components.
-
3.
Manufactured solid-fuel or gas-burning appliances.
-
The
inspector is not required to:
-
Determine adequacy of draft, perform a smoke test,
or dismantle or remove any component.
-
Examine the structural integrity of fireplaces
and chimneys.
-
Examine or operate ancillary or non-permanently
installed components.
SECTION
10 - Building Interior
-
Items to be identified and reported:
-
Walls, ceilings and floors.
-
Security
bars, ventilation components, and a representative
sampling of doors and windows.
-
Stairs, handrails, and guardrails.
-
Permanently installed cabinet and countertop surfaces.
-
Safety glazing in locations subject to human impact.
-
The inspector is not required to:
-
Operate
or evaluate security bar release and opening mechanisms,
whether interior or exterior, including compliance with
local, state, or federal standards.
-
Determine whether a building is secure from
forcible or unauthorized entry.
-
Evaluate the condition of floor, wall or
ceiling finishes or coverings, or other surfaces for other
than evidence of moisture damage.
-
Examine window or door coverings or treatments.
-
Evaluate fastening of countertops, furniture or
cabinets supported by floors, ceilings and/or walls.
-
Evaluate separation walls, ceilings, and floors,
including, but not limited to, the fire- resistivity or
acoustical characteristics, between dwelling units.
-
Examine the interior concrete slab-on-grade when
concealed by any floor coverings.
-
Operate or evaluate safety features of any
garage door opener unless included as an inspection
option per Section 11.
SECTION
11 (OPTIONAL) - Other Built-In Appliances and
Systems
The inspector may examine any of the following
at his/her discretion, as agreed with client:
Attic
power vents, central vacuum, cook-tops and exhaust fans, dishwashers,
food waste disposers, garage door openers, hydrotherapy tubs,
ovens, microwave ovens, refrigerators, freezers, trash compactors,
or whole-house fans.
-
Items to be identified and reported:
-
Optional
systems, components and appliances
specifically examined during the inspection.
-
Basic
operation of optional systems, components
and appliances specifically included in the inspection.
-
The inspector is not required to:
-
Activate
any system or appliance that is shut down.
-
Operate or evaluate any system, component,
or appliance that does not respond to normal
user controls.
-
Operate
any gas appliance that requires the use of a match
or other remote burner lighting device.
-
Operate
any system or appliance that requires the
use of special codes, keys, combinations, or devices.
-
Operate
any system, component, or appliance
where damage may occur.
-
Determine thermostat(s) calibration, adequacy of
heating elements, operate or evaluate self-cleaning
oven cycles, signal lights, or automatic setbacks or clocks.
-
Determine
leakage from microwave ovens.
-
Determine
the presence or operation of backdraft damper devices
in exhaust devices.
-
Examine
any sauna, steam-jenny, kiln, clothes washing or drying
machine, toaster, ice-maker, coffee-maker, can-opener,
bread-warmer, blender, instant hot water dispenser, or
any other similar small, ancillary or non-built-in
appliances.
SECTION
12 (OPTIONAL) - Pools and Spas
The inspector may examine the following at his/her
discretion, as agreed with client:
-
Items
to be identified and reported:
-
Location
and type of pool or spa examined.
-
Conditions
limiting or otherwise inhibiting inspection.
-
Enclosure
and related gates.
-
Hardscaping
and drainage related to the inspected pool or spa.
-
Condition
of visible portions of systems, structures,
or components.
-
Normally
necessary and present equipment such as: lights, pumps,
heaters, filters, and related mechanical and electrical
connections.
-
The
inspector is not required to:
-
Examine
any above-ground, movable, freestanding or otherwise non-permanently
installed pool or spa, or self-contained equipment.
-
Come
into contact with pool or spa water to examine the
system, structure, or components.
-
Determine
adequacy of spa jet water force or bubble effect.
-
Determine
structural integrity or leakage of any kind.
-
Evaluate
thermostat(s) or their calibration, heating elements, chemical
dispensers, water chemistry or conditioning devices, low
voltage or computer controls, timers, sweeps or cleaners,
pool or spa covers and related components.
-
Operate
or evaluate filter backwash systems.
-
Examine accessories, such as, but not limited to:
aerators or air-blowers, diving or jump boards, ladders,
skimmers, slides or steps.
Section 13 (Optional)-Manufactured Homes
The inspector may examine the following at his/her
discretion, as agreed with the client:
-
Items to be identified and reported:
-
Where
applicable the inspection shall be performed in
accordance with the Standards of Practice of the California
Real Estate Inspection Association (CREIA). The
inspector shall use US Dept. of Housing & Urban
Development (HUD) and Calif. State Department of Housing
& Community Development (HCD) regulations to determine
if a system or component has a material
defect.
-
LIMITATIONS, EXCEPTIONS AND EXCLUSIONS
*Note:
All limitations, exceptions and exclusions apply equally to
mandatory and optional Sections.
-
The
inspector may exclude from the inspection any system,
structure, or component of the building
which is inaccessible, concealed from view, or cannot
be inspected due to circumstances beyond the control of
the inspector, or which the client has agreed is
not to be inspected. If an inspector excludes any
specific system, structure, or component
of the building from the inspection, the inspector
shall confirm in the report such specific system,
structure, or component of the building
not inspected and the reason(s) for such exclusion(s).
-
The
inspector may limit the inspection to individual
specific systems, structures, or components
of the building. In such event, the inspector
shall confirm in the report that the inspection has
been limited to such individual specific systems,
structures, and components of the building.
-
The following are excluded from the scope of a real estate
inspection unless specifically agreed otherwise between
the inspector and the client:
- Systems,
structures, or components not specifically
identified in these Standards.
-
Environmental hazards or conditions, including,
but not limited to, toxic, reactive, combustible, corrosive
contaminants, wildfire, geologic or flood.
-
Examination of conditions related to animals,
rodents, insects, wood-destroying insects, organisms,
mold, and mildew.
-
Geotechnical, engineering, structural, architectural,
geological, hydrological, land surveying or soils-related
examinations.
-
Certain factors relating to any systems, structures,
or components of the building, including,
but not limited to: adequacy, efficiency, durability
or remaining useful life, costs to repair, replace or
operate, fair market value, marketability, quality,
or advisability of purchase.
-
Systems, structures, or components,
of the building which are not permanently
installed.
-
Determination of compliance with installation guidelines,
manufacturers' specifications, building codes,
ordinances, regulations, covenants, or other restrictions,
including local interpretations thereof.
-
Common areas, or systems, structures,
or components thereof, including, but not limited
to, those of a common interest development as defined
in California Civil Code Section 1351 et seq.
-
The
inspector is not required to perform any of the following
as part of a real estate inspection:
-
Move
any personal items or other obstruction(s) such as,
but not limited to: furniture, floor or wall coverings,
window coverings, snow, ice, water, debris, and foliage
which may obstruct visibility or access.
-
Determine causes for the need of repair or replacement,
or specify repair or replacement procedures or materials.
-
Determine existence of latent deficiencies or
defects.
-
Dismantle any system, structure,
or component, or perform any intrusive
or destructive examination, test or analysis.
-
Obtain or review information from any third-parties
including, but not limited to: government agencies (such
as permits), component or system manufacturers
(including product defects, recalls or similar notices),
contractors, managers, sellers, occupants, neighbors,
consultants, homeowner or similar associations, attorneys,
agents or brokers.
-
Activate or operate any system or component
that is shut down or does not respond to normal
user controls, nor access any area or operate
any component or system which may jeopardize
the safety of the inspector, or any other person
or thing.
-
Research the history of a property, report on
its potential for alteration, modification, extendibility,
or its suitability for a specific or proposed use or
occupancy.
-
Offer any form of guarantee or warranty.
-
Examine or evaluate the acoustical or
other nuisance characteristics of any system,
structure, or component of a building,
complex, adjoining properties, or neighborhood.
-
Operate or evaluate any recreational system,
structure or component.
-
Operate or evaluate low voltage electrical
(less than single-phase line voltage, typically 120-volts),
antennas, security systems, cable or satellite
television, telephone, remote controls, radio controls,
timers, intercoms, computers, photo-electric, motion
sensing, or other such similar non-primary electrical
power devices, components, or systems.
-
Use any special equipment to examine any
system, structure, or component
of a building.
-
Probe or exert pressure on any component, system
or structure.
-
Examine or evaluate fire-resistive qualities
of any system, structure or component
of the building.
-
Examine every individual component of
a system or structure, where such components
are typically replicated, including, but not limited
to: doors, windows, switches and receptacles. A representative
sampling may be performed in order to examine
such systems, structures, or components
of a building.
-
Determine the age of construction or installation
of any system, structure, or component
of a building, or differentiate between original
construction or subsequent additions, improvements,
renovations or replacements thereto.
-
GLOSSARY of TERMS
*Note:
All definitions apply to derivatives of these terms when italicized
in the text.
Accessible:
Can be approached or entered by the inspector safely
without difficulty or damage to the system, structure,
or component.
Appliance:
See "Component."
Appropriate
persons: An individual other than inspector herein,
qualified by virtue of special knowledge, training or resources
to further examine a system, structure, or component,
as in the manner of a specialist.
Basic operation:
The fundamental function of a component or appliance
(e.g., the bake and broil elements of an oven), but not those
ancillary to its use (e.g., an oven self-cleaning cycle or timer,
thermostat or clock).
Building:
The primary building subject of the inspection,
designed and erected for the purpose of human occupancy or use
(e.g. dwelling).
Built-in:
See "Permanently installed."
Component:
A permanently installed appliance, fixture,
element, or part of a system.
Condition:
The plainly visible and conspicuous state of being of a material
object or thing.
Cross-connection:
A connection between two otherwise separate systems, one
of which is potable water and the other waste, sewage or other
source of contamination.
Destructive:
To demolish, damage, or probe any system, structure,
or component, or to dismantle any system
or component that would not be taken apart by an ordinary
person in the course of normal maintenance.
Determine:
To arrive at an opinion or conclusion pursuant to examination.
Disconnected:
See "Shut down."
Dismantle:
See "Destructive." Functional Drainage: The emptying
of a plumbing fixture in a reasonable amount of time, without
overflow when another fixture is drained simultaneously.
Enter:
See "Accessible."
Evaluate:
To assess the systems, structures, or components
of a building.
Evidence:
Plainly visible and conspicuous material objects or other things
presented to the senses that would tend to produce conviction
in the mind of an ordinary person as to the existence or non-existence
of a fact.
Examine:
To visually look for and identify material defects in systems,
structures, or components of a building through
a non-invasive, physical inspection.
Fixture:
See "Component."
Function:
Performing its normal, proper and characteristic action.
Functional
Drainage: The emptying of a plumbing fixture in a reasonable
amount of time, without overflow when another fixture is
drained simultaneously.
Functional
Flow: A reasonable flow of water supply at the highest and
farthest fixture from the building main when another
fixture is operated simultaneously.
Further
Evaluation: A degree of examination beyond that of a typical
and customary non-invasive physical examination. Inspection:
The act of performing a real estate inspection.
Inspection:
The act of performing a real estate inspection.
Inspector:
One who performs a real estate inspection.
Intrusive:
See "Destructive."
Malfunction:
Failure to perform its normal, proper and characteristic action.
Material
defect: (Refer to Section I, "Definitions and Scope" Paragraph
B).
Normal
user controls: Devices that would be operated by the
ordinary occupants of a building, requiring no specialized
skill or knowledge.
Operate:
To cause systems or equipment to function with normal
user controls.
Operational:
Systems or components capable of being safely operated.
Permanently
Installed: Fixed in place (e.g. screwed, bolted, or nailed),
as distinct from components, systems, or appliances
considered portable or freestanding.
Primary
building: A building that an inspector has agreed
to inspect, excluding all accessory buildings with the
exception of the primary parking structure.
Primary
parking structure: A building for the purpose of vehicle
storage associated with the primary building.
Real Estate
Inspection: (Refer to Section I, "Definitions and Scope" Paragraph
A).
Report:
The inspection report is a written document prepared
for a fee and issued after a real estate inspection identifying
and describing the inspected systems, structures,
and components of the building and identifying material
defects discovered therein.
Representative
sampling: A small quantity of components of any system
or structure enough like others in its class or kind to
serve as an example of its class or kind.
Shut down:
Turned off, inactive, not in-service, non-operational.
Special
equipment: Any tools or devices other than those normally
used by an inspector to perform a typical and customary
non-invasive physical examination of the systems, structures,
and components of a building, including, but not
limited to: levels, probes, meters, video or audio devices and
measuring devices.
Structure:
An assemblage of various systems and components
to function as a whole.
System:
An assemblage of various components to function
as a whole.
Technically
exhaustive: A comprehensive and detailed examination beyond
the scope of a real estate inspection which would include,
but would not be limited to: specialized knowledge or training,
special equipment, measurements, calculations, testing,
research, or analysis.
Download the
Standards of Practice
(PDF: 6k)
Adobe
Reader is required to read these .pdf files. Click on Adobe icon
to download a free version of reader software if not already installed
on your system.
©
Copyright 2003-2004 California
Real Estate Inspection Association. All rights reserved.
1445
N. Sunrise Way, Suite 101 Palm Springs, CA 92262
Phone (800) 848-7342 * (760) 318-2115 Fax: (760) 318-2117 Email
Us: Info@creia.org
CREIA
is a nonprofit education & credentialing organization to benefit
consumers and professionals
|
|
 |